Rated 5 based on 1 product reviews
New Millennium Building Systems

Steel Joists, Roof Deck and Long-Span Composite Floor Deck

CONTACT INFO
1690 Broadway St.
Bldg. 19, Ste. 160
Fort Wayne, IN 46802
Phone: 260-321-8080
Continuing Education Logo
Request for information New Millennium Building Systems Contact Us / RFI
SOCIAL

Inverted N Deck is the 3" N-Dek profile placed in the inverted position for a unique ceiling aesthetic appearance. The finished look provides a smooth ceiling appearance with heavy shadow lines. INA-Dek is a 3" deep, wide rib, inverted, acoustical structural roof deck unit that provides a support surface for various types of roofing materials with an NRC rating of 0.80 when used with rigid roofing insulation.

- Hide Gallery
Inverted N Deck

Inverted N Deck  

1

Revit BIM Files for Inverted N Deck

Structural Roof Deck: N-Dek

CAD Drawings for Inverted N Deck
N-R-CMU-001 - Non-load Bearing CMU Wall - Ridge Condition
download: view:
N-R-CMU-002 - Load Bearing CMU Wall - Ridge Condition
download: view:
N-R-CMU-005 - Non-load Bearing CMU Wall - Interior Condition
download: view:
N-R-CMU-006 - Load Bearing CMU Wall - Interior Condition
download: view:
N-R-CON-001 - Non-load Bearing Concrete Wall - Ridge Condition
download: view:
N-R-CON-002 - Load Bearing Concrete Wall - Ridge Condition
download: view:
N-R-CON-005 - Non-load Bearing Concrete Wall - Interior Condition
download: view:
N-R-CON-006 - Load Bearing Concrete Wall - Interior Condition
download: view:
N-R-LGS-001 - Light Gauge Steel Truss - Ridge Condition
download: view:
N-R-LGS-005 - Non-load Bearing Light Gauge Steel Wall - Interior Condition
download: view:
N-R-LGS-006 - Load Bearing Light Gauge Steel Wall - Interior Condition
download: view:
N-R-P-001 - Roof Purlins - Ridge Condition
download: view:
N-R-RJ-001 - Roof Joist - Ridge Condition
download: view:
N-R-RJ-003 - Roof Joist - Valley Condition
download: view:
N-R-RJ-006 - Roof Joist - Interior Condition
download: view:
N-R-WF-002 - Wide Flange Beam - Ridge Condition
download: view:
N-R-WF-004 - Wide Flange Beam - Valley Condition
download: view:
N-R-WF-005 - Non-load Bearing Wide Flange Beam - Interior Condition
download: view:
N-R-WF-006 - Load Bearing Wide Flange Beam - Interior Condition
download: view:
Specifications for Inverted N Deck
05 31 00
application/vnd.openxmlformats-officedocument.wordprocessingml.document application/vnd.openxmlformats-officedocument.wordprocessingml.document application/msword
application/rtf application/wordperfect text/plain
RFI text/html VIEW
 
Catalogs for Inverted N Deck
Videos for Inverted N Deck
New Millennium Building Systems video of New Millennium Building Systems
2014-12-16T00:00:00+00:00Z
(New Millennium Building Systems) request for information
New Millennium Building Systems video of Optimize your building design and construction - New Millennium Building Systems
2019-12-10T00:00:00+00:00Z
(New Millennium Building Systems) request for information