Rated 5 based on 1 product reviews
New Millennium Building Systems

Steel Joists, Roof Deck and Long-Span Composite Floor Deck

CONTACT INFO
1690 Broadway St.
Bldg. 19, Ste. 160
Fort Wayne, IN 46802
Phone: 260-321-8080
Continuing Education Logo
Request for information New Millennium Building Systems Contact Us / RFI
SOCIAL

Cellular Deep-Dek® is a single cell (hat) unit with the liner panel that provides a support surface for various component roof systems. It can be used as a secondary structural member to provide for lateral force distribution to the structure's vertical force resisting systems. Cellular Deep-Dek™ products produce a smooth underside surface with subtle shadow lines for a clean finished look.

  • Exceptional performance: wind resistance, snow loads, seismic, etc.
  • Simplified installation with Dek-Knek™ Sidelap Attachment System
  • Available as an acoustic deck with NRC ratings as follows: type 4.5 value of 1.00; type 6 value of 1.00; type 7.5 value of 1.05
  • Cellular Deep-Dek™ 4.5, 6, and 7.5 are ICC approved
- Hide Gallery
Cellular Deep-Dek® Roof Deck

Cellular Deep-Dek® Roof Deck  

1

Revit BIM Files for Cellular Deep-Dek® Roof Deck

Structural Decks: Cellular-Deep-Dek

CAD Drawings for Cellular Deep-Dek® Roof Deck

Deep-Dek 4.5  

D4.5-R-CMU-001 - Non-load Bearing CMU Wall - Ridge Condition
download: view:
D4.5-R-CMU-002 - Load Bearing CMU Wall - Ridge Condition
download: view:
D4.5-R-CMU-005 - Non-load Bearing CMU Wall - Interior Condition
download: view:
D4.5-R-CMU-006 - Load Bearing CMU Wall - Interior Condition
download: view:
D4.5-R-CON-001 - Non-load Bearing Concrete Wall - Ridge Condition
download: view:
D4.5-R-CON-002 - Load Bearing Concrete Wall - Ridge Condition
download: view:
D4.5-R-CON-005 - Non-load Bearing Concrete Wall - Interior Condition
download: view:
D4.5-R-CON-006 - Load Bearing Concrete Wall - Interior Condition
download: view:
D4.5-R-LGS-001 - Light Gauge Steel Truss - Ridge Condition
download: view:
D4.5-R-LGS-005 - Non-load Bearing Light Gauge Steel Wall - Interior Condition
download: view:
D4.5-R-LGS-006 - Load Bearing Light Gauge Steel Wall - Interior Condition
download: view:
D4.5-R-P-001 - Roof Purlins - Ridge Condition
download: view:
D4.5-R-RJ-001 - Roof Joist - Ridge Condition
download: view:
D4.5-R-RJ-003 - Roof Joist - Valley Condition
download: view:
D4.5-R-WF-002 - Wide Flange Beam - Ridge Condition
download: view:
D4.5-R-WF-004 - Wide Flange Beam - Valley Condition
download: view:
D4.5-R-WF-005 - Non-load Bearing Wide Flange Beam - Interior Condition
download: view:
D4.5-R-WF-006 - Load Bearing Wide Flange Beam - Interior Condition
download: view:
Specifications for Cellular Deep-Dek® Roof Deck
05 31 00
application/vnd.openxmlformats-officedocument.wordprocessingml.document application/vnd.openxmlformats-officedocument.wordprocessingml.document application/msword
application/rtf application/wordperfect text/plain
RFI text/html VIEW
 
Catalogs for Cellular Deep-Dek® Roof Deck
Videos for Cellular Deep-Dek® Roof Deck
New Millennium Building Systems video of New Millennium Building Systems
2014-12-16T00:00:00+00:00Z
(New Millennium Building Systems) request for information
New Millennium Building Systems video of Optimize your building design and construction - New Millennium Building Systems
2019-12-10T00:00:00+00:00Z
(New Millennium Building Systems) request for information